Reliable Supplier Metal Syringe Filters - Instrument For SPE Cartridges – BM Life Science

Instrument For SPE

The series is divided into three categories:

1、Negative pressure filtration(Vacuum Manifold) For SPE cartridges&plates

2Instrument For SPE cartridges

1Negative pressure filtration(Vacuum Manifold) For SPE cartridges&plates

  23

Product Parameter

Product Category: Solid Phase Extraction Instrument,Vacuum Manifold

Function:Compound solid phase extraction, target sample filtration, adsorption, separation, extraction, purification and concentration

Purpose:It works well with multi-well plates, enabling filtration and extraction at the same time, and can be used in nucleic acid purification, solid phase extraction, protein precipitation.

Channel No.: 12-24-48-96 cartridges, 96&384 well plates

Extraction method: Negative pressure

Specification: Applicable to 1ml, 3ml, 6ml, 12ml SPE cartridges, 96 &384 well plates or other specifications

Printing LOGO:OK

Mode of supply:OEM/ODM

Description of products

The instrument is a solid phase extractor designed and developed for research institutes and biological companies in the field of life sciences. It is suitable for centrifugal columns with Ruhr interfaces, SPE cartridges, and 96/384 well filter plates with skirts.

an Automation SPE Instrument.It’s designed and developed for scientific research institutes and biological companies in the fields of life sciences, chemical analysis, food safety inspection.It is suitable for all SPE cartridges & 96/384 well filtration and collection plates.

The instrument is a high-throughput supporting equipment for the extraction and separation of biological samples. It is mainly used for the desalination and concentration of primers, nucleic acid, plasmid, and DNA extraction and separation, protein, polypeptide desalination, and concentration. Extraction of harmful substances from food test samples, pretreatment of chemical analysis samples, etc.. Working principle: vacuum pump is used to produce negative pressure on the extraction equipment, which causes the reagent to complete the process of pre-treatment of the entire biological sample by extracting the columns&plates.

The instrument is simple to operate and can handle 24/96/384 samples at the same time with 24 single columns and 96/384 well filter plates and deep well plates. It serves the purpose of separation, extraction, concentration, desalination, purification, and recovery of solid liquid from 24/96/384 samples.

Product characteristics

★Non-standard customization: It can be tailored and crafted according to customer requirements.

★Various specifications: supporting two types of cover plates, suitable for the use of 96/384 well filtering and collection plates of most specifications on the market.

★Various functions: Plate solid phase extractors can not only satisfy the use of 96/384 well filtration and collection plates, but also satisfy the use of different specifications and quantities of columns.

★High value for money: Columns&96/384 well filtration and collection plates for our own research and development, injection molding production, the use of matching consumables will make the cost of customers lower.

★The machine is made of stainless steel and advanced aluminum alloy. The box phosphates and multi-layer epoxy resin is sprayed. The entire machine is suitable for ultraviolet and alcohol sterilization treatment. The treated equipment can be used in the clean room and ultra-clean work table, and the pollution source is small. Capable of meeting relevant environmental requirements in the biological industry.

Order information

12/24 Vacuum Manifold

96/384 Vacuum Manifold

Compatible Type Vacuum ManifoldSuitable for  cartridges&plates

OtherVacuum Manifolds accept customer customization.

Welcome all new and old customers to inquire, discuss cooperation, seek common development!

 

2Instrument For SPE cartridges

 

Product Parameter

Product Category: Solid Phase Extraction Instrument

Function: Compound solid phase extraction, target sample filtration, adsorption, separation, extraction, purification and concentration

Channel No.: 8

Extraction method: positive pressure &negative pressure

Specification: 1ml, 3ml, 6ml, 12ml SPE cartridges

Printing LOGO:OK

Mode of supplyOEM/ODM

Description of products

The instrument is a semi-automatic solid phase extraction instrument.It’s designed and developed for scientific research institutes and biological companies in the fields of life sciences.It is suitable for various SPE cartridges.

The 8-channel solid phase extraction instrument is widely used in pharmaceutical hygiene, environmental protection, commodity inspection, tap water and chemical production laboratories. In the process of sample processing, the flow rate of various solutions is accurately controlled in an automatic manner. At the same time, it has positive pressure eluting, large volume continuous sampling and timing functions, ensuring the recovery and purity of the target analysis material, and reducing relative deviations. To avoid cross-contamination between samples, multiple samples can be processed at the same time to further improve the work efficiency, operation and maintenance is very simple.

The device is simple to operate and can be used with 8 SPE cartridges. It can handle 8 biological samples at the same time and serve the purpose of separation, extraction, concentration, desalination, purification, and recovery of 8 biological samples at the same time.

Product characteristics

★Non-standard customization: It can be tailored and crafted according to customer requirements.

★Channel control: One person operation can be processed 1-8 samples at the same time, greatly improving work efficiency.

★Precision control: motors and automatic pumps adopt high-precision automatic technology, low energy consumption, accurate speed control, single flow rate 0.01-10.85 ml/min, support large volume sample intake and positive pressure elution, avoid cross-contamination.

Various functions: equipped with company specific work software module; A variety of output methods can be selected to connect computer operations.

Excellent equipment: good extraction speed consistency, easy to control and adjust; Small column and its supporting plastic pipes and joints are resistant to acid and alkali, organic solvents, oxidant corrosion.

★High value for money: expendable columns/Frits/SPE cartridges for our own research and development, injection molding production, the use of matching consumables will make the cost of customers lower.

★The machine is made of stainless steel and advanced aluminum alloy. The box phosphates and multi-layer epoxy resin is sprayed. The entire machine is suitable for ultraviolet and alcohol sterilization treatment. The treated equipment can be used in the clean room and ultra-clean work table, and the pollution source is small. Capable of meeting relevant environmental requirements in the biological industry.

Order information

★ Instrument For 8-12 channel

★ Other Instruments for Solid Phase Extraction accept customer customization.

This series of products accept customer personalized customization, welcome all new and old customers to inquire, discuss cooperation, seek common development!

 


  • Reliable Supplier Metal Syringe Filters - Instrument For SPE Cartridges – BM Life Science Related Video: