Leading Manufacturer for Manifold Filtration Assembly - C8/SCX (octyl/sulfonic acid SPE column) – BM Life Science

overview:

C8/SCX is the extraction column (C8/ SCX), which is composed of silica gel as matrix C8 and strong cation exchange SCX packing in combination with the optimized proportion, and provides dual retention mechanism. The C8 functional groups interact with the hydrophobic groups of the analyte, while the SCX has an interaction with the proton. Because of these strong interactions, stronger flushing conditions can be used to remove the common extracts that may interfere with UV detection or cause LC-MS ion suppression. There is no closure of the stationary phase, which can increase the interaction between the residual silyl alcohol base and the polar analyte, thus helping to enhance retention.

details:

Matrix:Silica
Functional Group:Octyl,Phenyl sulfonic acid
Mechanism of Action:Reverse phase extraction, strong Cation exchange
Particle Size: 40-75μm
Surface Area:510 m2 /g
Application: Soil;Water;Body fluids(plasma/urine etc.);Food;Oil
Typical applications: The functional groups of C8 / SCX are composed of octyl and sulfonic acid based on the ratio bond, which have a dual retention function:the octyl provides medium hydrophobic action, and sulfonic acid base provides strong cation exchange In the case of excessive adsorption of C18 and C8, as well as the strong retention of SCX, it can be used as the extraction column of C8 / SCX mixed mode

Sorbents Form Specification Pcs/pk Cat.No
C8/SAX Cartridge 30mg/1ml 100 SPEC8SAX130
100mg/1ml 100 SPEC8SAX1100
200mg/3ml 50 SPEC8SAX3200
500mg/3ml 50 SPEC8SAX3500
200mg/6ml 30 SPEC8SAX6200
500mg/6ml 30 SPEC8SAX6500
1g/6ml 30 SPEC8SAX61000
1g/12ml 20 SPEC8SAX121000
2g/12ml 20 SPEC8SAX122000
96Plates 96×50mg 1 SPEC8SAX9650
96×100mg 1 SPEC8SAX96100
384Plates 384×10mg 1 SPEC8SAX38410
Sorbent 100g Bottle SPEC8SAX100

Sorbent Information

Matrix:Silica     Functional Group:Octyl&Quaternary ammonium salt         Mechanism of Action:Reverse phase extraction, strong anion exchange          Particle Size:45-75μm            Surface Area:510m2/g

Application

Soil;Water; Body Fluids(plasma/urine etc.);Food;Medicine

Typical Applications

The functional groups of C8 / SAX are composed of octyl and quaternary ammonium salts, which are combined byproportion and have a double retention function: octyl provides medium hydrophobic function and quaternary ammoniumprovides strong anion exchange In the case of excessive adsorption of C18 and C8, and the ability of SAX retention to be too strong, it can be used as the extraction column of C8 / SAX mixed mode

    ava (5) ava (6)


  • Leading Manufacturer for Manifold Filtration Assembly - C8/SCX (octyl/sulfonic acid SPE column) – BM Life Science Related Video: